| HS Code | 539030 |
| Product Name | AXELERON Cable Compound CS L-3364 NT |
| Type | Jelly Compound |
| Application | Filling compound for telecommunication cables |
| Appearance | Translucent gel |
| Color | Light |
| Penetration | 180-210 (1/10 mm at 25°C) |
| Drop Point | > 170°C |
| Density | 0.87–0.89 g/cm³ at 25°C |
| Oil Separator | < 1.0% at 70°C (168 hours) |
| Water Content | < 0.1% |
| Corrosivity | Non-corrosive to copper and aluminum |
| Compatibility | Compatible with polyethylene and polypropylene cable materials |
| Electrical Properties | High electrical resistivity |
| Operating Temperature Range | -40°C to +70°C |
| Oxidation Stability | High |
As an accredited AXELERON Cable Compound CS L-3364 NT factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | AXELERON Cable Compound CS L-3364 NT is packaged in 25 kg polyethylene-lined paper bags, labeled with product name and batch details. |
| Container Loading (20′ FCL) | Container Loading (20′ FCL): AXELERON Cable Compound CS L-3364 NT is typically shipped 16-18 metric tons per 20-foot container, palletized. |
| Shipping | AXELERON Cable Compound CS L-3364 NT is shipped in sealed, moisture-proof containers to ensure product integrity. Typical packaging includes steel drums or high-grade plastic pails. All shipments comply with relevant transportation regulations and are clearly labeled with hazard information for safe handling, storage, and transport. |
| Storage | AXELERON Cable Compound CS L-3364 NT should be stored in a cool, dry, and well-ventilated area, away from direct sunlight and sources of heat. Keep containers tightly closed and avoid exposure to moisture or contaminants. Store at recommended temperatures as provided in the product’s Safety Data Sheet to maintain quality and prevent potential hazards or degradation. |
| Shelf Life | AXELERON Cable Compound CS L-3364 NT has a shelf life of 24 months when stored in original, unopened containers. |
AXELERON Cable Compound CS L-3364 NT plays a critical role in demanding cable and wire manufacturing operations where enhanced insulation and sheathing performance are required. As a manufacturer, we support specialized clients in industries such as power transmission, telecommunication, automotive wiring, and data cable fabrication, addressing complex regulatory, process, and performance demands.
Power cable manufacturers incorporate this compound as the primary insulation layer for both medium and low voltage cables. Our material maintains dielectric strength and thermomechanical stability throughout continuous production, with melt blending and extruding steps strictly controlled for uniformity. Operators choose AXELERON Cable Compound CS L-3364 NT to meet electrical grid requirements, where performance under continuous thermal load and mechanical stress in underground, duct, or tray installations is paramount for reliability and safety.
Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
Telecommunication and data cable producers select CS L-3364 NT as an exterior sheath to guard against environmental and mechanical exposure. The compound grants high resistance to water ingress, chemical attack, and abrasion during installation or service. Processing teams extrude a precise thickness over cabled conductors, achieving targeted flame retardance and UV stability for indoor and outdoor utility networks. In environments where long-term protection and durability define service life, consistent control of surface quality and extrusion rate is essential.
Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
The automotive sector utilizes this compound for jacketing on multi-core wiring harnesses, demanding consistent flexibility, abrasion resistance, and thermal performance in dynamic vehicular conditions. Our material integrates directly into high-speed harness lines where extruder precision, adhesion to sublayers, and surface finish control are vital for downstream assembly. Cable makers employ tailored thermal stabilization additives to meet unique under-hood and passenger compartment standards, producing jacketed harnesses that undergo rigorous vibration, fluid immersion, and flex testing before OEM delivery.
Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
Manufacturers of cables for submerged or highly flexible industrial use rely on CS L-3364 NT as both an inner bedding and external sheath. The compound displays stable physical properties under prolonged water, oil, and chemical exposure, making it suitable for continuous flexing or submerged pump cables. Production lines must manage moisture during compounding and extrusion to avoid insulation breakdown, carefully calibrated for each sheath thickness. The compound also supports flame retardant performance required for harsh service areas.
Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
Competitive AXELERON Cable Compound CS L-3364 NT prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8615365186327 or mail to sales3@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8615365186327
Email: sales3@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Across factories and electrical networks, the health of a cable can shape uptime, worker safety, and critical communications. Over decades, cable manufacturers have battled moisture, shifting temperatures, and the subtle tolls of time. At the core, we have learned that cable compound isn’t “just” filler. Every ounce, every polymer chain, and every droplet of additive must pull its weight against the elements. AXELERON Cable Compound CS L-3364 NT stands as the outcome of years at the bench, on the line, and in the field, speaking the language of hands-on cable making.
CS L-3364 NT was developed to address the most persistent threats to cable performance—water ingress, dielectric breakdown, and insulation migration. Our chemists aimed for a material that supports the entire lifespan of a modern electrical or telecom cable, pushing back against common failures. Formulated with a precise blend of high-purity polyolefins and stabilizers, this compound provides a reliable non-dripping gel suitable for a full range of sheathing processes used in both new and retrofit projects.
The difference between CS L-3364 NT and other compounds often lands in the details. Some cable compounds run after years in the field, dripping into cable troughs or pooling at the lowest points, setting the stage for insulation voids and signal failure. CS L-3364 NT was engineered around consistency, with thermal stability curves showing it resists migration up to 90°C. No unstable thickening agents, no volatile mineral oils, nothing that will volatilize at the first surge or summer heatwave.
Across our line, only compounds passing rigorous moisture penetration and electrical resistance tests see the light of full-scale production. CS L-3364 NT’s key property—near-zero bleed-through—matters in every batch we make. Cable extruders don’t slow for leaks or sticky rewinds, and project failures rarely send polite warnings. Inside buried power cables and above-ground fiber, this compound has shown itself under rain, freeze-thaw cycles, and near coastal salt sprays.
In our production lines, the compound shows a soft, waxy consistency at ambient conditions, simplifying dosing and pumping. Process operators prefer it for its short cooling time; sheathing lines rarely face clogging or gelling problems in the gears and bath. This, in our experience, reduces downtime and minimizes offcuts. End-users have written in noting how maintenance intervals extend, as cable joints remain protected and require less inspection.
Plenty of suppliers offer off-the-shelf compounds with a promise of water blockage. We have all seen what can happen to a cable sleeved in inferior gel—inject moisture, wait a few months, and corrosion creeps at the first crack or gap in the sheath. Our research team worked side-by-side with field engineers to build CS L-3364 NT specifically for the tough standards set by critical infrastructure projects. This product handles submersion, soaks, and even steam ingress events with minimal mass loss.
What’s more, CS L-3364 NT was trialed across a variety of conductor surfaces. It shows strong adhesion to both copper and aluminum cores, avoiding air gaps where micro-condensation can gather. For those responsible for fiber optics, the compound’s careful viscosity and buffer compatibility means it doesn’t wick down the cable into splice trays or junctions, a problem that makes maintenance a time-consuming task.
Our process engineers have seen countless compositions run through extruders and cable lines. Every blend teaches its own lesson, sometimes by what fails as much as what succeeds. As we ran CS L-3364 NT through multiple production campaigns, we tracked its impact on fill rate, its behavior in long-haul shipping, and its durability in outdoor installations. We listened when our customers asked for a solution that would not bleed under high cable load cycles or in vertical installations.
In one utility project, engineers reported a line of legacy cables suffering from insulation voids and irregular resistance readings after just eight years underground. Swapping to CS L-3364 NT produced immediate gains: moisture content at cable cores dropped, insulation sheath flexibility held up after freeze-thaw tests, and conductor corrosion slowed dramatically. Our partnerships with these teams forged the fine adjustments in our compound’s recipe. With every feedback cycle, our approach changes, reflecting a commitment to process transparency and visible results.
The latest trends in wire and cable—higher voltages, smart sensing, and modular connectors—ask more from flame-retardant and hydrophobic compounds. Future-ready cables run smaller conductors at higher voltages, with less bulk to spare for protection. Our CS L-3364 NT doesn’t just fill voids—it resists electrical tracking, supports signal clarity, and avoids hardening over time. We chose stabilizers and antioxidants that work together, helping the compound survive thermal spikes and acid exposure from soil leachates.
Our technical teams test every lot against changing standards, both from regional authorities and original equipment manufacturers. CS L-3364 NT has passed multiple dielectric breakdown benchmarks and does not embrittle cable sheaths after repeated flex cycles. Feedback from installers in humid climates shows that even after years of high humidity, the compound maintains its sealing power, protecting multi-core bundles from condensation. This feature helps prevent signal dropouts in data lines and N+1 failures in power distribution circuits. As grid designs shift toward renewable feeds and distributed energy, long cable runs stretch through diverse terrains and climates—precisely the environments where inferior compounds reveal their weaknesses.
Quality assurance at our facility starts long before mixing any masterbatch. We source polymers from traceable suppliers, rejecting shipments that fall outside strict clarity and impurity standards. Each batch undergoes melt flow index testing, as cable makers count on predictable flow properties. A too-thick gel risks process clogs; a runny compound won’t stay put under the sheath. CS L-3364 NT’s optimized viscosity sits in a sweet spot, proven on multiple sheathing lines at both high and low throughput.
Our operators perform hands-on mass checks and visual inspections at every step. In addition, accelerated aging chambers challenge the compound to weeks of UV, heat, and salt spray. We believe that a cable is only as dependable as every meter of compound in its core. That’s why direct feedback loops between production, field users, and our lab continue to shape future versions and carry lessons through to every batch. This philosophy drives the repeatable quality of CS L-3364 NT.
Working alongside cable layers and field technicians, we have come to appreciate the hidden battles they face. Moisture doesn’t announce itself; by the time damage shows, it’s already late. Nobody enjoys tackling sticky, contaminated cable cores or finding that the blocking gel broke down after a few hot summers. CS L-3364 NT stands up to repeated handling, mechanical shocks, and vibration, staying put against shaking and bending when the cable is pulled through rough conduit.
Feedback from teams working elevated lines and buried installations drove several upgrades in our formulation. Installers often work in hard-to-access sites and ask for a cable compound that wipes off tools easily, doesn’t stain hands, and stays clean even after laying long runs. They also highlight the importance of compounds free from strong odors or skin-irritating residues. CS L-3364 NT addresses these concerns—its neutral smell, non-staining finish, and skin-safe profile simplify the job and shorten downtime for routine checks.
Earlier generations of cable compounds relied heavily on mineral oils and soft paraffins. These materials offered basic water blocking but could leach from the cable sheath in high temperature extremes. Some common gels crack at freeze point, while others thin out and run in the heat. Both scenarios create weak points that shorten cable life. CS L-3364 NT’s use of high-molecular weight base polymers brings stability, enhanced adhesion, and superior resistance to thermal cycling.
Where some compounds leave an oily surface that attracts dust and makes further processing difficult, CS L-3364 NT sets to a tack-free finish under expected load and pressure. Traditional blends sometimes trap pockets of air, which over time form condensation sites and corrosion starters. Our material flows and self-heals during sheathing, reducing these pockets and lowering future risk. Users see less cable scrap, fewer process defects, and, crucially, a material strong enough to form a barrier that lasts.
Cable budgets stretch further if compounds perform well for the entire cable lifespan. Installers and procurement officers notice the difference in compounds through both upfront processing and long-term maintenance. CS L-3364 NT doesn’t gum up machines or require frequent line cleaning—a critical advantage where line time costs real money. Its resistance to aging and environmental stress means cable cores avoid waterlogging, limiting the need for costly field intervention or cable replacement.
We worked with utility partners to evaluate lifecycle costs over ten years. The results pointed not only to a longer cable life but to fewer break-ins for maintenance, lower corrosion rates, and more predictable insulation resistance. Downtime drops when crews aren’t sent repeating the same job year after year. CS L-3364 NT returns tangible dollars to those who think in total cost of ownership, not just input price.
Safety regulations shape chemical formulation choices. Every ingredient in CS L-3364 NT meets rigorous standards in terms of health and environmentally responsible sourcing. Our blend excludes banned flame retardants and volatile hydrocarbon solvents. Field trials show no hazardous off-gassing, protecting both workers and end-users. Laboratory toxicology screens confirm the absence of skin-irritants, and routine emissions checks catch any trace components that exceed allowable thresholds.
Conversations with certification bodies and internal compliance teams keep us aligned to changing legal and ecological requirements. Our lab runs every proposed formulation against not just today’s codes, but those likely on the horizon. Continuous dialogue between chemists and regulatory specialists ensures we remain ahead of compliance changes. With CS L-3364 NT, cable manufacturers and installers have a product that ticks every compliance box while still delivering the practical features needed on the ground.
The current era of cable and connectivity demands new compounds that keep up with rapid infrastructure changes. Renewable energy, electric vehicles, and data-driven smart grids all run on cables subjected to new environments—some above hot roofs, others deep under water or soil. CS L-3364 NT was field-validated on solar array cables, underwater telecom lines, and high-flex robotics harnesses well before commercial release. We took direct feedback from these trial partners and tuned the product with their toughest challenges in mind.
In one pilot, a customer running underwater cables saw an end to patch failures along tidal flats after switching to our compound. This kind of feedback gives us direct evidence that CS L-3364 NT is making a difference, not only in test labs, but in the environments that matter most.
Our team learned early that the best cable compounds come from hands-on work, not just from standards documents. Lab researchers, process engineers, and field crew line up their notes to shape every batch. We continue to listen as customers describe new challenges and changing installation environments. We pay attention to unusual requests—whether it’s a variation to support a rare installation process or tweaks for a custom extrusion line.
We track traceability through every drum and lot, and every product that leaves our loading dock comes with support from engineers who have seen compounds succeed, and sometimes fail, in the toughest conditions. CS L-3364 NT is the product of these shared experiences, built to support real crews in real infrastructure.
Digitalization, distributed energy, and infrastructure longevity will continue to stretch the cable industry. The perfect compound keeps cables dry, safe, and electrically sound through every surge and season. CS L-3364 NT stands ready today, built with the fundamentals we’ve found in decades of cable making—quality inputs, rigorous field feedback, and a deep respect for those who install and maintain the world’s vital networks. We will keep pushing our research and listening to every insight gained from the factory, the warehouse, and the field, ensuring that every new challenge finds a practical answer in the next version of our compounds.