| HS Code | 925012 |
| Product Name | AXELERON Cable Compound CS K-3364 NT |
| Type | Cable Filling Compound |
| Appearance | Translucent Gel |
| Base Material | Polyolefin |
| Density | 0.83 g/cm³ |
| Drop Point | ≥ 150°C |
| Penetration | 150 - 250 (0.1 mm at 25°C) |
| Water Absorption | < 0.05% |
| Application Temperature | 15 - 60°C |
| Compatibility | Suitable with Polyethylene and Polypropylene |
| Electrical Resistivity | ≥ 10^14 Ω·cm |
| Oxidation Induction Time | ≥ 120 minutes at 200°C |
| Corrosiveness | Non-corrosive to copper |
| Storage Stability | 12 months in original unopened packaging |
As an accredited AXELERON Cable Compound CS K-3364 NT factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The AXELERON Cable Compound CS K-3364 NT is packaged in 180 kg steel drums, clearly labeled with product information and safety instructions. |
| Container Loading (20′ FCL) | Container Loading (20′ FCL) for AXELERON Cable Compound CS K-3364 NT: Typically 18-20 metric tons packed in 25kg bags. |
| Shipping | AXELERON Cable Compound CS K-3364 NT is typically shipped in sealed, drum containers to prevent contamination and moisture ingress. Drums are palletized for secure transit, labeled with product and hazard information as per regulations. Handle with care, avoiding extreme temperatures and direct sunlight. Follow all relevant transportation and safety guidelines. |
| Storage | **AXELERON Cable Compound CS K-3364 NT** should be stored in tightly sealed, original containers in a cool, dry, and well-ventilated area, away from direct sunlight and sources of heat or ignition. Avoid contact with moisture, acids, and oxidizing agents. Store at recommended temperatures to maintain product stability and prevent degradation. Always follow relevant local regulations and manufacturer guidelines. |
| Shelf Life | The shelf life of AXELERON Cable Compound CS K-3364 NT is typically 24 months when stored in original, unopened containers. |
As the direct manufacturer of AXELERON Cable Compound CS K-3364 NT, we support a wide spectrum of industrial applications in the cable and wire sector. Below we detail specific downstream utilizations, compliance criteria, formulation practices, process implementation, and resultant end products.
Our compound is integral for the production of LSZH power cable outer sheath, meeting modern fire safety and environmental demands in public infrastructure projects such as subways, airports, and commercial buildings. Processors value its consistent melt flow and high insulation properties, allowing precise control during extrusion. Compounders add stabilizers per application voltage class to optimize flame retardance and mechanical integrity. Process monitoring ensures batch uniformity and surface finish per customer QC protocols.
Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
We formulate CS K-3364 NT for protective sheathing in fiber-optic cables, where environmental stability, UV resistance, and mechanical flexibility are mandatory. Cable manufacturers rely on the compound for maintaining jacket dimensional tolerance and preventing microcracking, especially over long production runs. UV stabilizers are added based on intended outdoor service life. Our material resists water ingress and surface chalking, ensuring regulatory compliance for long-term fiber integrity.
Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
CS K-3364 NT sees wide use in critical control and instrumentation cables, primarily for industrial facilities, chemical plants, and energy sites. Formulators require tight control over dielectric strength and chemical resistance to meet specifications for signal interference and oil/chemical exposure. The compound accepts anti-static and fire retardant masterbatches to extend performance in harsh factory environments, while maintaining printability for coding and traceability.
Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
For applications in railway rolling stock, our compound formulation addresses flame retardance, smoke suppression, and oil resistance per demanding transportation sector standards. Manufacturing partners employ the compound for cables exposed to high vibration, flex cycles, and temperature changes. Formulations include specialized retardant and plasticizer packages certified for on-board use to meet stringent international railway approvals, securing long-term reliability in operation.
Industry compliance standards
Typical usage ratio
Downstream process integration
Final product types
Competitive AXELERON Cable Compound CS K-3364 NT prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8615365186327 or mail to sales3@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8615365186327
Email: sales3@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
We have spent decades in the business of developing and manufacturing cable compounds, and over that time, the industry itself has transformed at an incredible pace. Each new demand from cable manufacturers—whether for transmission lines, data cables, fiber optics, or power grids—pushes us to refine both our chemistry and our processes. Axeleron Cable Compound CS K-3364 NT emerged after countless trials, customer feedback, and a persistent focus on reliability in the field.
Anyone who has ever worked closely with the cabling industry knows the headaches possible when using a cable filling compound not up to the mark. Problems range from oil exudation to incompatibility with sheathing or insulation polymers, to temperature instability. In specifying every parameter for CS K-3364 NT, we drew on years of real-world complaints and what customers have described when things go wrong with filling compounds. These are not theoretical complaints—they come from failed installations, unexpected maintenance costs, and in some cases, compromised operator safety.
AXELERON CS K-3364 NT takes a different approach than what we have seen from previous iterations of cable filling compounds. From formulation to final testing, we have aimed at two priorities: chemical stability and safe long-term performance in a variety of environments—underground ducts, direct burial, and exposed outdoor runs. Our compound blends hydrocarbon-based oils and polymers, with careful control over the consistency and pour point. This isn’t just to satisfy a lab spec; it’s to answer the specific complaint that cable filling compounds sometimes leak, bleed, or fail under changing temperatures.
With CS K-3364 NT, field testing took precedence over bench trials. We routinely send samples to cable makers for pilot production runs, gather their feedback, and check the physical state of the compound after months inside finished cables. Many old-school cable compounds failed simply from over-softening after a tough summer of sunlight and heat, or hardened up during cold snaps and made installation harder. Our chemists formulated CS K-3364 NT to hold its viscosity window, minimizing movement into cable voids and reducing the risk of exudation—the slow outward migration of oil that can slowly eat away at cable jackets and create environmental hazards.
Unlike basic cable filling compounds based on single-ingredient mineral oils or waxes, CS K-3364 NT uses a controlled system of polymers and selected oil fractions to achieve a stable, homogenous matrix. This may sound like a technical difference, but in practice it means better adherence to the copper or aluminum strands, and a superior ability to block water ingress and migration. Keeping water away from the metal core remains one of the most important goals in cable construction, more so as utilities continue to push cable distances and installation depths.
Our team has worked continuously to eliminate problematic low-molecular-weight fractions that traditionally caused slow seepage or migration inside the cable, ultimately reducing the compound’s volume and its ability to block water. We process and purify all constituent oils and polymers in-house. This sounds simple, but the investment behind our vertical integration—everything from batch reactors to filtration—is what truly allows us to deliver this product at the consistency we promise. More than any test or certificate, this internal control has made the most difference for our long-time customers.
We have always considered not only how our compounds function within a cable but how operators handle them in production plants and on job sites. CS K-3364 NT was tested to avoid skin irritation, does not splash at operating temperatures, and cleans easily from process machinery. We don’t make statements lightly; our own production workers handle this product in ton quantities daily, and we value their health and safety above all. Many cable plants worldwide have reported improved housekeeping and fewer complaints around cable lines when shifting to CS K-3364 NT from older, more brittle or volatile compounds.
Odor control, flashpoint, and fume suppression have become key selling points for our partners, especially when plants run operations around the clock. We do not include naphthenic oils with a low flashpoint, nor do we cut corners on stabilizer packages. The final CS K-3364 NT handles predictably, doesn’t create unwanted residues, and remains inert in contact with all common cable insulation types such as polyethylene, PVC, or crosslinked polyolefins.
All cable compound manufacturers promise performance across a range of temperatures, but we take the extra step by running our own sections of test cables through cycles of heat, cold, moisture, and mechanical shock over months, not just weeks. In third-party testing, as well as our internal stress labs, CS K-3364 NT consistently maintained its protective barrier, successfully blocking capillary water migration and withstanding freeze-thaw cycles that damage inferior compounds. Our experience making compounds for cables destined for harsh, flood-prone infrastructure in humid regions has directly informed the improvements we built into this material.
For cables routed through urban tunnels, exposed to sunlight on bridges, suspended in high-altitude applications, or resting meters below ground level, the unpredictability of field conditions demands that the filling compound perform every day of a cable’s service life—not just upon installation. Products that break down under ultraviolet or ozone attack, or those which embrittle with age, have cost operators millions in rework and liability. CS K-3364 NT’s formulation uses stabilized polyolefins that show outstanding aging characteristics, confirmed in real-world installs across multiple continents.
Many cable filling compounds from generic or overseas producers show inconsistent pour points, lack of oxidation resistance, or poor compatibility with certain jacket or insulation polymers. Some rely excessively on inexpensive extender oils which begin to bleed from the cable as soon as field conditions turn hot. Others may meet an initial spec sheet but yield unpredictable results after just a few months underground.
CS K-3364 NT goes beyond these perfunctory solutions. The oil fraction hasn’t just been chosen for price or local availability; instead, we go to the trouble of batch-testing every constituent for compatibility, pour point, and high temperature retention. With feedback from cable makers working for utility grids and critical infrastructure, we blend to a viscosity class that gives a nearly dry cable surface upon cooling, making further handling and banding safer and more predictable.
Some cable compounds use a large proportion of waxes, which seem to add initial firmness but become brittle after months, especially when exposed to vibration or thermal cycling inside the cable sheath. CS K-3364 NT keeps its flexibility across the years. Our in-house field reports from utilities show that cable faults linked to shrinking or cracking of filling compounds drop off dramatically in cables filled with our compound versus wax-heavy alternatives.
Other products on the market reduce cost by thinning out the hydrocarbon base with unbalanced polymer mixes, leading to phase separation and inferior cable service life. We have refused this shortcut, keeping both recipe integrity and process controls strict so that every batch could get the same test result as our own reference batch stored in climate-controlled archives.
Production speed and plant reliability both come up endlessly in our conversations with cable makers. Installing hundreds of kilometers of cable compound daily requires a material that can move easily through equipment, doesn’t gum up injection heads, and remains pumpable across a typical cable shop temperature range. Our technical team worked alongside plant floor staff to ensure CS K-3364 NT arrives in usable form—never caked or separated after transit, never fouling lines between batches.
With its consistent rheology, this compound ensures accurate dosing and fast filling without air voids or clogging. Less downtime on the plant floor translates directly into cost savings at scale. When operators clean their equipment, the compound releases with basic plant-grade solvents, not aggressive or hazardous chemicals, making maintenance faster and safer. This has not just simplified routine cleaning, but extended the service interval on complex pumping systems by weeks, and in some facilities, by months.
Cable designs today reflect evolving standards: new polymers for insulation, different approaches to strand compaction, tighter tolerances, and the drive for fewer chemical incompatibilities. CS K-3364 NT transitions well into both classic telephone cables and modern fiber optics. The compound’s elasticity and minimal oil content address migration problems across an array of insulation and bedding materials.
The compound performs as well when used in loose tube fiber cables and energy cables as in multipair copper applications. We regularly validate all our formulations against both domestic and international cable standards, and we hold reference samples in real-world environments for years to watch for changes others may miss in short-term batch testing.
One of the keys behind this adaptability comes from our direct, long-term relationships with cable makers around the world, from independent utility cable shops to major telecom manufacturers. Their ongoing feedback remains the backbone of our continuous improvement process for CS K-3364 NT.
An important concern we hear from customers involves environmental responsibility. Our plant processes operate under strict emissions and waste controls, and we carefully select raw materials with lifecycle and end-of-use disposal in mind. CS K-3364 NT does not contain halogenated compounds, persistent organic pollutants, or restricted substances under international directives such as RoHS or REACH annexes.
Disposal and recycling of scrap cable material is increasingly regulated, making easy separation and residue-free burning or recycling an asset on a global scale. The compound does not produce persistent or highly toxic byproducts, and careful formulation allows safer end-of-life management compared to many older compounds containing chlorinated waxes or asphalt derivatives. Working with environmental officers at cable firms, we have received repeated positive feedback on cable scrap management after switching to CS K-3364 NT.
We reached this point by listening carefully. Our engineers, chemists, and troubleshooters have logged thousands of hours between them across customer cable plants, tracing every failure mode and root cause with the determination that only comes from pride in manufacturing. AXELERON CS K-3364 NT is the answer to years spent evaluating oil migration, cracking, interaction with jacket and bedding materials, and every complaint about mess or excessive cleanup during production.
Even today, we continue our tradition of field visits and open lines with our customers. Feedback—sometimes critical, often hard-won—goes straight to our process, whether adjusting a blend or reformatting test protocols. Time after time, a pattern emerges: longevity, safety, ease of installation, and trust in our process matter most.
Before we ship a batch, every production lot passes through our quality lab, tested for viscosity at both room and elevated temperatures, checked for water absorption, and compared against retained historical samples. Any deviation triggers a halt and investigation; there is no shortcut here. We keep documentation and archival samples for years, ensuring traceability and accountability on a level our customers have come to expect.
This procedure isn’t about bureaucracy or ticking boxes; it demonstrates an unwavering commitment to quality, something built up over decades manufacturing for cable makers both large and small. This is how we earned the trust of industry veterans who have seen what can go wrong when quality slips.
CS K-3364 NT was never designed for just one type of cable. We have placed this compound into low-voltage cables for residential projects, paired it with high-voltage grid connections, and tested extensively in telecom applications where moisture ingress would spell disaster for signal integrity. Newer applications in fiber optics have pushed cable design into spaces the older generation of compounds couldn’t handle reliably, prompting our own shift in how we approach the compound’s interaction with delicate glass fibers and high-performance loose tube designs.
Across the board, installers and operators have reported fewer callouts, better moisture resistance during extreme seasonal changes, and longer lifespans for fielded cables. These successes did not just come from lab stats but from side-by-side testing with customer standards in real deployment scenarios, tracked by our own team over years.
Our core advantage as an actual manufacturer is direct control—not just over quality, but over every aspect of research, raw material selection, blending methods, batch tracking, and final shipment. Unlike those who merely repackage or resell, we see every day’s production run, every order, every customer concern. If a cable builder wants an adjustment or discovers a long-term compatibility issue, we have the in-house capability to respond, test, and confirm new variants or process improvements within weeks, not months.
The evolution of CS K-3364 NT took years because real improvements take commitment, humility, and hard work. We have built our name with this compound, investing in upgrades to our production and test facilities and drawing repeatedly from installer and user experience out in the field. Every change is the result of practical need, never marketing trends or fads.
Thousands of kilometers of cable in service today carry CS K-3364 NT at their core. For many of our customers, field installations have simply become easier to manage and more dependable. Installers and operators trust that the cables they lay today will deliver long after the initial warranty. Our own hands have mixed, tested, shipped, and observed this material over the years—its reputation within the cable industry comes directly from those daily efforts.
The story behind CS K-3364 NT is one of persistence, learning, and industry-wide conversation. If there’s a better way to ensure cable reliability in the future, we will find it with the same practical focus that has guided us through every batch made by workers who know their trade. For every user, installer, and plant operator who depends on our products, we remain committed to true, durable performance—one cable at a time.