    • Product Name: DOWTHERM Heat Transfer Fluid SR-1
    • Chemical Name (IUPAC): Monoethylene glycol
    • CAS No.: 107-21-1
    • Chemical Formula: C2H6O2
    • Form/Physical State: Liquid
    • Factroy Site: Yudu County, Ganzhou, Jiangxi, China
    • Price Inquiry: sales3@ascent-chem.com
    • Manufacturer: Dow Inc
    • CONTACT NOW
    VTB
    Specifications
    HS Code 248995
    Product Name DOWTHERM Heat Transfer Fluid SR-1
    Product Type Heat Transfer Fluid
    Color Pink
    Odor Mild
    Specific Gravity 60f 1.05 to 1.10
    Boiling Point > 105°C (> 221°F)
    Freezing Point -51°C (-60°F)
    Ph Concentrate 9.0 to 10.5
    Solubility In Water Complete
    Flash Point None
    Viscosity Cp 25c 5.8
    Main Ingredient Ethylene glycol
    Thermal Conductivity W Mk 25c 0.320
    Appearance Liquid

    As an accredited DOWTHERM Heat Transfer Fluid SR-1 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing DOWTHERM Heat Transfer Fluid SR-1 is packaged in a 55-gallon (208-liter) blue steel drum with clear product labeling and safety instructions.
    Container Loading (20′ FCL) DOWTHERM Heat Transfer Fluid SR-1 is shipped in 20′ FCL (Full Container Load) with bulk or drum packaging options.
    Shipping DOWTHERM Heat Transfer Fluid SR-1 is typically shipped in tightly sealed, corrosion-resistant drums or totes to prevent leakage and contamination. Packages are clearly labeled with hazard information according to DOT regulations. The fluid should be transported in climate-controlled vehicles to avoid extreme temperatures and handled using standard chemical safety procedures.
    Storage DOWTHERM Heat Transfer Fluid SR-1 should be stored in tightly closed, clearly labeled containers in a cool, dry, and well-ventilated area away from incompatible substances such as strong oxidizers. Protect from direct sunlight, excessive heat, and moisture. Secondary containment is recommended to prevent spills or leaks, and ensure all storage areas comply with local, state, and federal safety regulations.
    Shelf Life DOWTHERM Heat Transfer Fluid SR-1 has an indefinite shelf life when stored in unopened containers under proper conditions.
    Application of DOWTHERM Heat Transfer Fluid SR-1

    Applications of DOWTHERM Heat Transfer Fluid SR-1 in Industrial Manufacturing

    As a trusted producer of glycol-based heat transfer solutions, we supply DOWTHERM SR-1 to OEMs and industrial processors whose manufacturing operations require consistent temperature control and reliability. Below are specialized sectors where our material plays a critical role, detailing technical adoption and operational requirements throughout the production chain.

    1. Commercial HVAC and District Energy Systems

    Centralized heating and cooling systems in commercial buildings and municipal infrastructure rely on precise thermal regulation over prolonged operational cycles, often encountering extreme seasonal fluctuations. Our glycol fluid integrates directly into hydronic loop coolant circuits, sustaining flow performance and heat transfer even during freezing conditions, ensuring system longevity for campuses, hospitals, airports, and urban development projects.

    Industry compliance standards

    Typical usage ratio

    Downstream process integration

    Final product types

    2. Pharmaceutical API and Biotech Fermentation Cooling

    Active pharmaceutical ingredient (API) manufacturing and fermentation reactors require vigilant control of exothermic reaction temperatures to preserve yield and purity. Our fluid supports process chillers and secondary coolant loops, which directly interface with vessel jackets, vacuum condensers, and batch reactors, maintaining safe production runs for both small- and large-molecule drug synthesis.

    Industry compliance standards

    Typical usage ratio

    Downstream process integration

    Final product types

    3. Food and Beverage Process Cooling

    Industrial beverage manufacturers, dairies, and breweries use glycol-based fluids in closed-loop food plant refrigeration systems, preventing product spoilage and microbial proliferation during storage, pasteurization, and fermentation. Our material is suitable for indirect contact cooling where the integrity of finished food products must meet demanding regulatory oversight.

    Industry compliance standards

    Typical usage ratio

    Downstream process integration

    Final product types

    4. Renewable Energy and Solar Thermal Systems

    Solar heating installations, concentrating solar power (CSP) plants, and geothermal source loops utilize thermal transfer fluids for efficient energy capture, storage, and distribution across collector fields and heat storage tanks. Our glycol solution guards against freezing damage and underpins stable heat extraction even in prolonged low-ambient climates with cyclical start-stop operation cycles.

    Industry compliance standards

    Typical usage ratio

    Downstream process integration

    Final product types

    5. Industrial Refrigeration and Process Chillers

    Facilities producing chemicals, plastics, and electronics depend on large-scale refrigeration and cooling water recirculation for temperature-controlled manufacturing environments. Our heat transfer fluid ensures operational stability in secondary refrigeration loops, notably reducing freeze risk, minimizing fouling, and supporting uninterrupted batch or continuous production processes where equipment protection is paramount.

    Industry compliance standards

    Typical usage ratio

    Downstream process integration

    Final product types

    Free Quote

    Competitive DOWTHERM Heat Transfer Fluid SR-1 prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8615365186327 or mail to sales3@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615365186327

    Email: sales3@ascent-chem.com

    Inquiry

    Get Free Quote of Dow Inc

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    DOWTHERM Heat Transfer Fluid SR-1: Experience from the Production Floor

    Introduction to DOWTHERM SR-1 from the Manufacturer's Perspective

    Walking the workshop floor every day, we know first-hand that heating and cooling systems only function as well as the heat transfer fluids inside them. Over years of making industrial chemicals, our teams have seen system operators juggle dozens of requirements: corrosion resistance, thermal stability, pumpability at low temperatures, ease of system fill, life expectancy, and—just as crucial—worker safety. No shortcuts exist. This relentless focus on reliability and tangible performance led us to invest heavily in developing the DOWTHERM Heat Transfer Fluid SR-1. We set out to deliver a water-based glycol mixture that delivers consistent performance across thousands of HVAC and process cooling installations, season after season.

    SR-1’s Formulation in the Real World

    On paper, DOWTHERM SR-1 is an inhibited ethylene glycol-based fluid. In practice, every batch that leaves our facility reflects years of fine-tuning the chemical recipe so it works without fuss in the field. Ethylene glycol improves freeze protection and heat transfer, but what genuinely sets SR-1 apart is the corrosion inhibitor package baked into the blend. Cheaper alternatives without robust inhibitors can form acids and attack system metals, causing leaks and downtime nobody wants to deal with in the dead of winter or midsummer peak.

    We took lessons learned from failed competitor products encountered on site—pitting on copper, scale in aluminum, unsupported gasket swell in compressors—and reformulated the SR-1 additive mix. The result: system components last longer, routine maintenance calls involving flushes or acid washes drop, and pressure increases after startup remain well within design specs. From mixing tanks to filling lines, these practical improvements come directly from hands-on troubleshooting in industrial chillers and distributed building systems, not just a lab bench.

    SR-1’s Performance in Varied Operating Conditions

    We have manufactured batches destined for everything from suburban hotel chillers to pharmaceutical fermenter jackets. Winterization and freeze-burst prevention top most customers’ priorities, especially in climates with unpredictable cold snaps. SR-1’s low freezing point, tunable by changing the water-to-glycol ratio, gives design engineers and system owners the flexibility to protect piping as small as ¼ inch up to citywide loops without custom formulations. Some operators push glycol levels for deep-freeze applications; others opt for higher water fractions in moderate climates to enhance heat transfer. Both applications came up during pilot programs we ran alongside building managers, providing data-driven confidence before product rollout.

    Unlike propylene glycol options, ethylene glycol in SR-1 transfers heat with more efficiency, which is most apparent in large commercial systems or industrial heat exchangers. We’ve tested side-by-side against propylene glycol and watched as energy bills dip and system head pressures hold steady over months, translating to real savings that reach the bottom line. At the same time, these features matter little if the product is hard to handle. For installation teams, SR-1 pumps smoothly, doesn’t foam excessively during fill, and flushes cleanly when maintenance needs arise. These features stem from close ties with installers and their feedback, not just design specs.

    Material Compatibility and Long-Term System Life

    It’s easy to overlook the day-to-day toll water, glycol, and trace elements take on metal, elastomer, and plastic system parts. On production shifts, we often hear from customers working with mixed-metal systems built across several expansion phases and renovations. Our team has beta-tested SR-1 batches against copper, brass, cast iron, mild steel, and several grades of stainless. The corrosion inhibitors target the types of electrochemical reactions that pit tube sheets and foul heat exchanger plates, even during long equipment idling or startup and shutdown cycles, when untreated fluids can cause rapid oxidation.

    Minimized corrosion means less metal loss, reduced sludge buildup, and fewer stuck valves—backed by time-lapse inspections from our service techs several years after initial fills. These results show up in internal inspection logs and photos, not just printed graphs. Unlike generic uninhibited glycols, SR-1’s inhibitors also protect against scale and biological growth, both major culprits in dosing and spray system failures. We routinely deploy test loops using city water to check for long-term precipitation and biofouling, aiming for a product that works across soft and hard water conditions.

    Thermal Stability and Practical Maintenance Advantages

    Repeated heating and cooling cycles can break down many glycol blends, leaving behind acids and tars that degrade system integrity. Our QC labs monitor SR-1 samples pulled after years of service, checking for pH drift, color changes, and total acid number. In the field, this means the fluid resists thermal degradation and doesn’t need constant adjustment, unlike basic glycols that start strong and fade fast. We learned quickly from earlier versions: plant managers don’t want fluids that turn brown and attack pipes after a few hard winters. SR-1 holds its own through freeze-thaw cycles, even in older systems where fresh fill-ups might be years apart.

    Routine checks show that fill chemistry stays within specification, meaning fewer top-offs with inhibitors or balancing agents. For maintenance leads, this translates to less unplanned downtime, fewer preventative flushes, and easier compliance with equipment warranty conditions. We also pay attention to compatibility with common test kits, so on-site sampling delivers actionable results without the need for specialized training or equipment.

    Workplace Safety and Environmental Considerations

    As the manufacturer, we routinely train facility personnel using SR-1 in a variety of HVAC and industrial process environments. Ethylene glycol calls for appropriate handling due to its toxicity profile. Our focus has always included precise labeling, reliable safety data, and staff training materials so users cannot overlook safe transfer, spill containment, and environmental management practices. We support contractors and maintenance techs with hands-on sessions, not just paperwork, walking them through PPE use, spill kit deployment, and the right way to test for leaks using dye markers.

    On environmental compliance, we monitor wastewater handling at our production sites. Product shipped to the customer contains only the inhibitors proven to keep systems safe and compliant with regional discharge standards. We partner with waste management teams to ensure that spent glycol can be reclaimed or disposed of according to evolving EPA and state guidelines. This helps avoid regulatory headaches for end-users, who sometimes struggle to keep up with disposal laws after busy heating or cooling seasons.

    On-site, efforts to reduce packaging waste, drum rinsate, and leftover tote cleaning effluents have steadily improved. Bulk shipments and refillable containers are increasingly favored by large institutional buyers seeking to minimize on-site pollution.

    Differences in Application: DOWTHERM SR-1 vs. Alternatives

    No one fluid handles every situation. In making SR-1, we set out to combine strong heat transfer with corrosion protection for a wide band of temperature ranges, knowing many customers balance budget, system age, and operational needs. Unlike food-grade propylene glycol blends, which suit food and beverage applications and potable water adjacency, SR-1 is made for non-ingestible closed systems where efficiency comes first.

    Compared to unmixed water, SR-1 prevents winter freeze and boiling in the same system. Operators see value in the fluid’s temperature window, protecting lines against subzero lows and high process heat loads. It outperforms uninhibited glycol mixes, which can cause catastrophic internal rust or scale within a single heating season, especially in older pipes or mixed-metal assemblies that show up in many retrofitted plants. SR-1 often features in bid specifications for commercial cooling towers, data center chillers, and long-run hydronic heating.

    We frequently receive questions about SR-1 versus DOWFROST propylene glycol fluids. For installations where incidental contact with food, beverage, or potable water lines could occur, we recommend DOWFROST. In cooling and heating systems aimed at capacity and lifetime service, especially where maintenance manpower or budgets are limited, SR-1's higher heat transfer coefficient appeals to engineers and operations teams calculating return on investment.

    Everyday Factory Experience: What Sets SR-1 Apart

    Batch after batch, the most consistent feedback we hear from installers and O&M staff using SR-1 is its predictability. The fluid pours clean, mixes evenly with water, and provides visible color for leak detection under most lighting conditions. Our blending equipment operates with tight controls, ensuring inhibitor concentration doesn’t fluctuate from one drum or tote to the next. This level of process control gives building managers and mechanical contractors peace of mind, knowing what comes out of every container matches the last one they used—even across large phased installations.

    From the first day on the fill deck, staff receive in-depth training, walking them through blend verification steps, batch records, and container washing protocols. Our internal audits and product recalls remain among the lowest in the category, reflecting a hands-on commitment to both product consistency and overall safety.

    On cold mornings or during unplanned refills after a system extension, SR-1 brings the advantage of straightforward handling. Workers don’t encounter unexpected foaming or residue in fill tanks and pumps, simplifying purges and refills in the field. Returns and troubleshooting calls due to system clogging or unexplained deposits have steadily dropped as a direct consequence of these ongoing adjustments and practical improvements made to our process over years of manufacturing experience.

    User Stories: Lessons Learned in the Field

    Direct feedback from mechanical contractors and facility techs using SR-1 shapes the way we continue to tweak the product. One industrial park client switched from a no-name glycol blend after a corrosion leak led to downtime in their distribution lines. They reported that after refilling with SR-1 and following our guidance on system cleaning, operational problems fell off. This wasn’t a fortunate side effect; this sort of operational reliability comes from continuous investment in product formulation and support driven by what we see in the field.

    An OEM chiller manufacturer uses SR-1 as the default fill and ships their equipment worldwide. Their engineering staff track performance data on every system for warranty claims, and our fluid’s stability extended mean time between failures on pumps and seals. Short feedback loops—immediately documenting even small issues—let us respond quickly to concerns, refine batches, and retrain staff before problems spread.

    One hospital maintenance supervisor shared with us that routine glycol testing with SR-1 continues to save on chemical treatment and unplanned repairs—especially critical for their oncology and emergency wing HVAC, where temperature swings aren’t allowed. Their team relies on visible fluid color to spot leaks at a glance, saving troubleshooting time during the busiest shifts.

    Our Experience in Responding to Industry Change

    The last decade brought accelerated changes in regulatory compliance, system complexity, and customer demand for data transparency. For SR-1, these shifts meant modernizing plant controls, using automated dosing and blending systems to guarantee every container matches target specifications. Digital batch tracking and QC trending replaced paper logbooks, slashing error rates and cutting investigation time in the rare instance of a customer question.

    Our manufacturing lines run longer campaigns but with more frequent in-process checks. Any anomaly in pH, inhibitor content, or visual clarity triggers a hold, not a shipment. We know from experience that an ounce of prevention avoids costly field repairs and warranty headaches for everyone down the line. Customer audits don’t slow production, since data and in-line sensor checks are part of every lot reconciliation.

    We collaborate with equipment manufacturers and certification labs to align SR-1’s formulation with new gasket, elastomer, and metal requirements. These partnerships drive ongoing product reforms and allow swift adaptation whenever a new heat exchanger material or regulatory directive rolls out. As more jurisdictions regulate ethylene glycol use and disposal, our internal compliance team reviews formulation and documentation in lockstep, keeping shipments both legal and easy to handle for downstream partners.

    Addressing Emerging Issues: Glycol Management and System Diagnostics

    Large-scale building and industrial customers often flag issues with improper dilution ratios and invisible leaks, both of which undermanage system freeze protection and place unexpected stress on fluid chemistry. In response, our product specialists now walk SMEs and mechanics through fluid sampling procedures, dilution guidelines, and on-site test kit usage during project commissioning. We make sure SR-1 is shipped with user-facing guidance materials, not just a chemical drum and MSDS. This comes from years of fixing preventable issues in the field—mismanaged blends, missed leaks, and underdosed inhibitor top-ups—from plantrooms to remote telecommunications huts.

    Remote monitoring and connected controls are becoming more popular for large HVAC and chiller systems. SR-1’s consistent inhibitor package allows sensor-driven diagnostics to flag abnormal fluid chemistry or possible leaks before they become emergencies. Some building automation systems now integrate glycol sample checks into their regular maintenance screens, making SR-1 an easy match due to its chemical predictability and response to test kits from leading suppliers.

    Solutions based on Direct Experience

    Years at the production line taught us that delivering technical improvements without practical support won’t solve real-world problems. Customers ask for not just a better fluid, but a straightforward way to use it, maintain it, and measure system health. We work directly with service techs and facility staff to troubleshoot unexpected issues—be it a drop in freeze protection, cloudy samples, or questions on end-of-life fluid disposal.

    To address recurring maintenance challenges, our team developed a detailed glycol management guide, including best practices for sampling, top-offs, draining, and disposal unique to SR-1’s formulation. We regularly visit customer sites to train new staff on rapid isolation techniques for troubleshooting and leak management, all drawn from incidents witnessed in the field and feedback channels reached through our 24/7 plant hotline. This hands-on approach closes the gap between chemical production and operational success, reducing problems like underdosing, overmixing, and misidentification.

    Building on this experience, we invested in pilot projects to test SR-1 in extended temperature and cyclical load environments. Product stability, ease of on-site monitoring, and system uptime all receive as much attention as thermal performance, with continuous feedback fueling new improvements.

    The Manufacturer’s Commitment Beyond Product Release

    From our vantage point as a heat transfer fluid producer, reliable system performance depends on alignment between product formulation, operator skill, and ongoing technical support. Every SR-1 batch undergoes rigorous field testing under simulated and actual system conditions, while guidance and troubleshooting support remain available long after product delivery. This commitment to reliability and continuous improvement reflects countless hours on the production floor, in maintenance bays, and at commissioning sites.

    We continue to refine SR-1’s chemistry in response to feedback from real-world installations—whether that’s a trend in seasonal system stress, new corrosion sources, or emerging regulatory concerns on glycol use and discharge. Daily production experience, frequent tech support dialogue, and honest engagement with system operators drive every modification to our product and service approach. By staying close to the challenges faced by our customers, our technicians, and our own teams, we deliver a heat transfer fluid that helps keep critical operations running safely and efficiently, year after year.